Megger 1005-265 Fused Test Lead Set with Probes and Clips, 1.25m, 2 Leads

Model: 1005-265 | UPC: 5036175229934

Megger 1005-265 Fused Test Lead Set with Probes and Clips, 1.25m, 2 Leads

Model: 1005-265 | UPC: 5036175229934

Fused probe and clip test lead set for all MIT and S1 15kV instruments.

Fused probe and clip test lead set for all MIT and S1 15kV instruments.

Sale Price $255.15 CAD
Regular Price $270.00 CAD
Availability 2 to 3 Weeks
Quantity

Megger 1005-265 Offers

Features

  • Large range to suit all applications
  • Unique locking HV insulated plugs
  • None detachable clips for safety with capacitance
  • Screened options for high noise environments
  • High quality silicon double insulated cable

Safety Warnings

  • The circuit under test must be switched off, deenergised, isolated and checked to be safe before insulation test connections are made. Make sure the circuit is not re-energised whilst the instrument is connected.
  • Circuit connections must not be touched during an insulation test.
  • After completing test, capacitive circuits must be completely discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharge, until required for use. This is to guard against any stored dielectric absorption charge subsequently being released thereby raising the voltage to potentially dangerous levels.
  • Test leads, including crocodile clips, must be in good order, clean, dry and with no broken or cracked insulation.
  • The lead set should not be used if any part of it is damaged.
  • These accessories are not designed to provide full levels of safety isolation to the operator if touched. The required physical dimensions would render this impractical. Safe working practices must be used.

Application Notes

These clips are designed for clamping on larger diameter test pieces but where space us at a premium. The insulation is designed only to protect the user from the output of Megger 5 kV, 10 kV and 15 kV insulation testers.

The clips cannon in any circumstances to relied on to protect the user from live systems above 600 V a.c in a CAT IV environment, or 1000 V a.c in a CAT III environment.

Megger 1005-265 Specifications

Dimensions 90 (L) X 41 (closed) mm
Jaw opening 20 mm dia max (clip)
Number in set 2
Double insulation rating 1 kV d.c
CAT Rating 600 V a.c CAT IV
Lead Length 1.25m
Insulation Rating 1 kV d.c
Cable type Flexible double insulated silicon
Fuse Rating FF500 mA 50 kA
Click here for complete specifications on the Megger 1005-265

What's included with the Megger 1005-265

  • Megger 1005-265 Fused Test Lead Set with Probes and Clips, 1.25m, 2 Leads

Ask a question about Megger 1005-265 Fused Test Lead Set with Probes and Clips, 1.25m, 2 Leads

Customer Reviews for the Megger 1005-265

Megger 1005-265 Offers

Features

  • Large range to suit all applications
  • Unique locking HV insulated plugs
  • None detachable clips for safety with capacitance
  • Screened options for high noise environments
  • High quality silicon double insulated cable

Safety Warnings

  • The circuit under test must be switched off, deenergised, isolated and checked to be safe before insulation test connections are made. Make sure the circuit is not re-energised whilst the instrument is connected.
  • Circuit connections must not be touched during an insulation test.
  • After completing test, capacitive circuits must be completely discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharged before disconnecting the test leads. Capacitive charges can be lethal.
  • Tested items should be firmly shorted out with a shorting link, after discharge, until required for use. This is to guard against any stored dielectric absorption charge subsequently being released thereby raising the voltage to potentially dangerous levels.
  • Test leads, including crocodile clips, must be in good order, clean, dry and with no broken or cracked insulation.
  • The lead set should not be used if any part of it is damaged.
  • These accessories are not designed to provide full levels of safety isolation to the operator if touched. The required physical dimensions would render this impractical. Safe working practices must be used.

Application Notes

These clips are designed for clamping on larger diameter test pieces but where space us at a premium. The insulation is designed only to protect the user from the output of Megger 5 kV, 10 kV and 15 kV insulation testers.

The clips cannon in any circumstances to relied on to protect the user from live systems above 600 V a.c in a CAT IV environment, or 1000 V a.c in a CAT III environment.

Megger 1005-265 Specifications

Dimensions 90 (L) X 41 (closed) mm
Jaw opening 20 mm dia max (clip)
Number in set 2
Double insulation rating 1 kV d.c
CAT Rating 600 V a.c CAT IV
Lead Length 1.25m
Insulation Rating 1 kV d.c
Cable type Flexible double insulated silicon
Fuse Rating FF500 mA 50 kA
Click here for complete specifications on the Megger 1005-265

What's included with the Megger 1005-265

  • Megger 1005-265 Fused Test Lead Set with Probes and Clips, 1.25m, 2 Leads

Ask a question about Megger 1005-265 Fused Test Lead Set with Probes and Clips, 1.25m, 2 Leads

Customer Reviews for the Megger 1005-265

More Megger Products