Featuring a 3 mΩ to 3000 Ω/300V DC battery tester for production line testing of high voltage battery packs and modules.
Featuring a 3 mΩ to 3000 Ω/300V DC battery tester for production line testing of high voltage battery packs and modules.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
This bench top battery tester supports simultaneous high-speed measurement of internal resistance and battery voltage for the ever-expanding production lines of increasingly larger lithium-ion low resistance batteries, and other battery packs for high voltage applications.
Features
Note: The comparison threshold values depend on the battery manufacturer, type, and capacity, and these must be established by the user.
Applications
| Maximum Applied Measurement Voltage | ±300 VDC rated input voltage ±300 VDC Max. rated voltage to earth |
| Resistance Measurement Ranges | 3 mΩ (Max. display 3.1000 mΩ, resolution 0.1 μΩ) to 3000 Ω (Max. display 3100.0 Ω, resolution 100 mΩ), 7 ranges Accuracy: 30 mΩ to 3000 Ω ranges, ±0.5% rdg. ±5 dgt. (Add ±3 dgt. for EX.FAST, or ±2 dgt. for FAST and MEDIUM) 3 mΩ range, ±0.5% rdg. ±10 dgt. (Add ±30 dgt. for EX.FAST, or ±10 dgt. for FAST, or ±5 dgt. for MEDIUM) Testing source frequency: 1 kHz ±0.2 Hz Testing current: 100 mA (3 mΩ range) to 10 μA (3000 Ω range) Open-circuit voltage: 25 V peak (3/30 mΩ ranges), 7 V peak (300 mΩ range), 4 V peak (3 Ω to 3000 Ω ranges) |
| Voltage Measurement Ranges | 6 VDC (resolution 10 μV) to 300 VDC (resolution 1 mV), 3 ranges Accuracy: ±0.01% rdg. ±3 dgt. (Add ±3 dgt. for EX.FAST, or ±2 dgt. for FAST and MEDIUM) |
| Display | 31000 full digits (resistance), 600000 full digits (voltage), LED |
| Sampling Rate | Four steps, 4 ms (Extra-FAST), 12 ms (FAST), 35 ms (Medium), 150 ms (Slow) (Typ., sampling time depends on supply frequency settings and function) |
| Measurement Time | Response time + sampling rate, approx. 10 ms for measurements (Response time depends on reference values and the measurement object) |
| Comparator Functions | Judgment result: Hi/IN/Lo (resistance and voltage judged independently) Setting: Upper and lower limit, Deviation (%) from reference value Logical ANDed result: PASS/FAIL, calculates the logical AND of resistance and voltage judgment results Result display, beeper, or external I/O output, Open-collector (35 V, 50 mA DC max.) |
| Interfaces | External I/O, RS-232C, Printer (RS-232C) |
| Power Supply | 100 to 240 VAC, 50/60 Hz, 30 VA max. |
| Dimensions | 8.46 x 3.15 x 11.61" (215 x 80 x 295 mm) |
| Weight | 84.7 oz (2.4 kg) |
| Maximum Applied Measurement Voltage | ±300 VDC rated input voltage ±300 VDC Max. rated voltage to earth |
| Resistance Measurement Ranges | 3 mΩ (Max. display 3.1000 mΩ, resolution 0.1 μΩ) to 3000 Ω (Max. display 3100.0 Ω, resolution 100 mΩ), 7 ranges Accuracy: 30 mΩ to 3000 Ω ranges, ±0.5% rdg. ±5 dgt. (Add ±3 dgt. for EX.FAST, or ±2 dgt. for FAST and MEDIUM) 3 mΩ range, ±0.5% rdg. ±10 dgt. (Add ±30 dgt. for EX.FAST, or ±10 dgt. for FAST, or ±5 dgt. for MEDIUM) Testing source frequency: 1 kHz ±0.2 Hz Testing current: 100 mA (3 mΩ range) to 10 μA (3000 Ω range) Open-circuit voltage: 25 V peak (3/30 mΩ ranges), 7 V peak (300 mΩ range), 4 V peak (3 Ω to 3000 Ω ranges) |
| Voltage Measurement Ranges | 6 VDC (resolution 10 μV) to 300 VDC (resolution 1 mV), 3 ranges Accuracy: ±0.01% rdg. ±3 dgt. (Add ±3 dgt. for EX.FAST, or ±2 dgt. for FAST and MEDIUM) |
| Display | 31000 full digits (resistance), 600000 full digits (voltage), LED |
| Sampling Rate | Four steps, 4 ms (Extra-FAST), 12 ms (FAST), 35 ms (Medium), 150 ms (Slow) (Typ., sampling time depends on supply frequency settings and function) |
| Measurement Time | Response time + sampling rate, approx. 10 ms for measurements (Response time depends on reference values and the measurement object) |
| Comparator Functions | Judgment result: Hi/IN/Lo (resistance and voltage judged independently) Setting: Upper and lower limit, Deviation (%) from reference value Logical ANDed result: PASS/FAIL, calculates the logical AND of resistance and voltage judgment results Result display, beeper, or external I/O output, Open-collector (35 V, 50 mA DC max.) |
| Interfaces | External I/O, RS-232C, Printer (RS-232C) |
| Power Supply | 100 to 240 VAC, 50/60 Hz, 30 VA max. |
| Dimensions | 8.46 x 3.15 x 11.61" (215 x 80 x 295 mm) |
| Weight | 84.7 oz (2.4 kg) |