Fluke Networks 19800HD9 TS19 Test Set

Model: 19800HD9 | UPC: 754082038344

Fluke Networks 19800HD9 TS19 Test Set

Model: 19800HD9 | UPC: 754082038344

Complete with a rugged design, this telephone test set is a professional made for testing data lines. Accidental disruption of service can be avoided while testing data lines with the DataSafe feature while on monitor mode.

Complete with a rugged design, this telephone test set is a professional made for testing data lines. Accidental disruption of service can be avoided while testing data lines with the DataSafe feature while on monitor mode.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Fluke Networks 19800HD9 Offers

Features

  • High impedance DataSafeTM operation in monitor mode
  • Tone (DTMF) and pulse operation
  • Last number redial
  • Polarity indication in talk mode

Fluke Networks 19800HD9 Specifications

Electrical Specifications
Over-Voltage Protection Protected against over-voltages to 300 V
Transient Voltage Protection Protected against transient voltages to 1500 V
Loop Limit 2.4 kΩ maximum at 48 V DC (nominal 15 mA minimum loop current)
DC Resistance (Talk Mode) 150 Ω typical at 80 mA current
AC Impedance (Monitor Mode) Low impedance (Ring position) 600Ω at 1 KHz typical
High impedance (HI Z position) 100 k&937; minimum at 1 KHz
Rotary Dial Output Pulsing Rate: 10 pps +0.5 pps
Percent Break: 10 pps +0.5 pps
Interdigit: 800 ms typical
Leakage During Break: > 50 k&3937;
DTMF Output Tone Frequency: ±1% maximum
Level per Tone Pair: +2 dBm maximum, -8 dBm minimum
High versus Low Tone Difference: 4 dB maximum
Maximum Sound Level from Speaker 125 dB(A) above 20 μPa for less than 1 second
General Specifications
Temperature Operating: 23 to 104°F (-5 to 40°C)
Storage: -40 to 150.8°F (-40 to 66°C)
Altitude To 3,000 m (10,000 ft) maximum
Dimensions 8.75 x 2.375 x 3.375" (22.2 x 6.03 x 8.57 cm)
Weight 10.8 oz (0.3 kg)
Safety IEC 61010-1:2010, Pollution Degree 2, Category: None complies with CAN/CSA-C22.2 No. 61010-1

What's included with the Fluke Networks 19800HD9

  • Fluke Networks 19800HD9 TS19 Test Set

Ask a question about Fluke Networks 19800HD9 TS19 Test Set

Customer Reviews for the Fluke Networks 19800HD9

Fluke Networks 19800HD9 Offers

Features

  • High impedance DataSafeTM operation in monitor mode
  • Tone (DTMF) and pulse operation
  • Last number redial
  • Polarity indication in talk mode

Fluke Networks 19800HD9 Specifications

Electrical Specifications
Over-Voltage Protection Protected against over-voltages to 300 V
Transient Voltage Protection Protected against transient voltages to 1500 V
Loop Limit 2.4 kΩ maximum at 48 V DC (nominal 15 mA minimum loop current)
DC Resistance (Talk Mode) 150 Ω typical at 80 mA current
AC Impedance (Monitor Mode) Low impedance (Ring position) 600Ω at 1 KHz typical
High impedance (HI Z position) 100 k&937; minimum at 1 KHz
Rotary Dial Output Pulsing Rate: 10 pps +0.5 pps
Percent Break: 10 pps +0.5 pps
Interdigit: 800 ms typical
Leakage During Break: > 50 k&3937;
DTMF Output Tone Frequency: ±1% maximum
Level per Tone Pair: +2 dBm maximum, -8 dBm minimum
High versus Low Tone Difference: 4 dB maximum
Maximum Sound Level from Speaker 125 dB(A) above 20 μPa for less than 1 second
General Specifications
Temperature Operating: 23 to 104°F (-5 to 40°C)
Storage: -40 to 150.8°F (-40 to 66°C)
Altitude To 3,000 m (10,000 ft) maximum
Dimensions 8.75 x 2.375 x 3.375" (22.2 x 6.03 x 8.57 cm)
Weight 10.8 oz (0.3 kg)
Safety IEC 61010-1:2010, Pollution Degree 2, Category: None complies with CAN/CSA-C22.2 No. 61010-1

What's included with the Fluke Networks 19800HD9

  • Fluke Networks 19800HD9 TS19 Test Set