Delivers greater accuracy and clarity, making it an ideal test tool for plant maintenance engineers and technicians, and is designed to withstand harsh, dirty, and hazardous industrial conditions. With just one test tool, you will tackle just about any troubleshooting task.
Delivers greater accuracy and clarity, making it an ideal test tool for plant maintenance engineers and technicians, and is designed to withstand harsh, dirty, and hazardous industrial conditions. With just one test tool, you will tackle just about any troubleshooting task.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
A faster sample rate and higher bandwidth mean greater accuracy and clarity. The scope will capture and display unknown waveform shapes, amplitudes, and any disturbances. To display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate of the device being tested. The faster the sample interval, the more accurate and detailed the scope will display a signal edge (dV/dt) and peaks of any reflections or transients.
Features
Three-dimensional testing for industrial systems
Inspect input signals, output feedback loops or safety interlocks simultaneously to find a range of problems including:
Three-phase testing for diagnosing VSD, power inverters, and converters
Safely measure from mV to kV
Standard probes that cover a wide application range from mV to kV prepare you for anything from micro-electronics to heavy duty medium voltage electrical applications. Independent isolated inputs eliminate the risk of accidental ground short circuits by allowing you to make measurements in mixed circuits with separate ground references.
Take on the harshest conditions with the only IP-51-rated according to IEC60529
Rugged and shock-proof, the portable oscilloscope is built for harsh environments. The sealed cases protect them from dust, water vapor, drips, humidity and airborne pollutants, ensuring reliable and accurate performance every time you need them.
Work a full shift on a single charge
High-performance batteries take advantage of Li-Ion technology to keep you going strong for up to seven hours. And with the easy-access battery door you can make battery swaps fast.
Capture and share waveforms easily with USB connectivity
Two USB ports, electrically isolated from measurement input circuits offer you easy USB connectivity to a PC or USB memory devices. Store unlimited waveforms, screen captures or instrument setups to a USB memory device. Connect to a PC USB interface to transfer and archive critical measurement data using FlukeView software for windows.
See a stable display instantly with connect-and-view™ triggering
Connect-and-View™ automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable, and repeatable display of virtually any signal including motor drive and control signals. Expedites measuring several test-points in rapid succession.
Record up to 48 hours of high-resolution waveforms with ScopeRecord™
ScopeRecord memory stores up to 30,000 data points per channel, capturing intermittents and fast glitches.
Record up to 22 days with Trendplot™ paperless recorder to find intermittent faults
Intermittent faults can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, sags, or starting and stopping a motor can also cause a machine to stop. The TrendPlot function in the test tool helps find those faults by:
Applications
Infrared cameras, also called thermal imagers, are useful for troubleshooting motor problems as well as for monitoring motor condition for preventative maintenance in power generation, manufacturing and commercial plants. Thermal images of motors reveal their operating condition as indicated by surface temperature. Such condition monitoring is important as a way to avert many unexpected motor malfunctions in systems that are critical to manufacturing. The onset of motor failures can often be detected by a variety of techniques, including vibration, ultrasound and thermal imaging.
In this article, we cover why use thermal imaging and what to scan, as well as some notes on what to look for, including shaft misalignment.
Read the ArticleVertical Deflection | |
Bandwidth | 500 MHz |
Number of Channels | 4 channels |
Number of Scope Inputs | 4 input channels |
Input Sensitivity | 2 mV-100 V/div plus variable attenuation |
Accuracy | ±(2.1% of reading + 0.04 x range/div) at 5 mV/div to 100 V/div |
Horizontal Deflection | |
Maximum Real-Time Sample Rate | 5 GS/s (single channel) or 1.25GS/s per channel |
Maximum Record Length | 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ roll mode |
Maximum Record Length | ScopeRecord mode: 30,000 pts per input Scope mode: 10,000 pts per input |
Timing Accuracy | ±(0.01% of reading + 1 pixel) |
Voltage | |
DC Accuracy | ±(1.5% + 5 counts) |
AC True RMS Accuracy | 15 to 60 Hz: ±(1.5% + 10 counts) 60 Hz to 20 kHz: ±(2.5% + 15 counts) |
AC/DC True RMS Accuracy | 15 to 60 Hz: ±(1.5% + 10 counts) 60 Hz to 20 kHz: ±(2.5% + 15 counts) |
Ranges | 500 mV, 5, 50, 500, 1000 V |
General Specifications | |
Memory Locations | 30 waveform memories plus 10 recording memories plus 9 screen copy memories |
Display Size | 5 x 3.46" (127 x 88 mm) 6" (153 mm) diagonal LCD |
Resolution | 320 x 240 pixels |
Power Supply | Rechargeable, double capacity li-ion battery |
Dimensions | 10.5 x 7.5 x 2.8" (265 x 190 x 70 mm) |
Weight | 4.8 lbs (2.2 kg) including battery |
Click on a category to view a selection of compatible accessories with the Fluke 190-504/AM ScopeMeter Test Tool, 500 MHz, 4-channel.
Vertical Deflection | |
Bandwidth | 500 MHz |
Number of Channels | 4 channels |
Number of Scope Inputs | 4 input channels |
Input Sensitivity | 2 mV-100 V/div plus variable attenuation |
Accuracy | ±(2.1% of reading + 0.04 x range/div) at 5 mV/div to 100 V/div |
Horizontal Deflection | |
Maximum Real-Time Sample Rate | 5 GS/s (single channel) or 1.25GS/s per channel |
Maximum Record Length | 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ roll mode |
Maximum Record Length | ScopeRecord mode: 30,000 pts per input Scope mode: 10,000 pts per input |
Timing Accuracy | ±(0.01% of reading + 1 pixel) |
Voltage | |
DC Accuracy | ±(1.5% + 5 counts) |
AC True RMS Accuracy | 15 to 60 Hz: ±(1.5% + 10 counts) 60 Hz to 20 kHz: ±(2.5% + 15 counts) |
AC/DC True RMS Accuracy | 15 to 60 Hz: ±(1.5% + 10 counts) 60 Hz to 20 kHz: ±(2.5% + 15 counts) |
Ranges | 500 mV, 5, 50, 500, 1000 V |
General Specifications | |
Memory Locations | 30 waveform memories plus 10 recording memories plus 9 screen copy memories |
Display Size | 5 x 3.46" (127 x 88 mm) 6" (153 mm) diagonal LCD |
Resolution | 320 x 240 pixels |
Power Supply | Rechargeable, double capacity li-ion battery |
Dimensions | 10.5 x 7.5 x 2.8" (265 x 190 x 70 mm) |
Weight | 4.8 lbs (2.2 kg) including battery |